性感美女骚虎视频在线播放_anquya俺去了俺来了_国产作爱免费一级视频_亞洲國產精品酒店絲襪高跟_久久久www黄色网站_国产一级性爱AV_成人大黄全免费网站_欧美一区二区丝袜美腿_野花社区韩国免费观看_婷婷深爱五月

0576-86382900
Hot tel:0576-86382900

Dalan Electric Machinery Manufacturer's popular three-phase asynchronous motor test specifications, all come to increase the knowledge! uuuuuuuuu

2019-01-18 11:59:19   1055

Standardize motor inspection operation, mainly verify whether the performance of three-phase asynchronous motor meets the requirements of relevant standards and technical conditions; whether there are various defects affecting the operation in design and manufacture; Today, Dalan Motor Factory will introduce its inspection specifications to you.

Standardize motor inspection operation, mainly to verify whether the performance of three-phase asynchronous motor meets the requirements of relevant standards and technical conditions; whether there are various defects affecting the operation in design and manufacture; today, Dalan motor manufacturer will introduce its inspection specifications to you.

I. scope

This specification is applicable to factory test and type test of three-phase asynchronous motor (hereinafter referred to as motor).

2. Citation criteria:

Basic technical requirements of GB755 rotary motor GB1032 three-phase asynchronous motor test method.

3. Measurement instruments and test methods for testing:

Measuring instruments and test methods are in accordance with GB1032.

4. Exit test:

1) Each motor must pass the factory test before it can leave the factory.

2) Out-of-factory test projects include:

(a) Mechanical inspection: turning the shaft by hand to see whether the motor is smooth, light and non-stagnant, to check whether the parts are complete, correct, non-bumping rust, and the motor surface paint is dry, complete, uniform, non-stain, damage, cracks and other phenomena.

B) Measurement of insulation resistance between stator windings and chassis: The insulation resistance of motor should not be less than 1M_in actual cold state, and not less than 0.38 M_ (rated voltage 380V) or 0.66 M_ (rated voltage 660V) after thermal state or temperature rise test. The value of insulation resistance of high voltage motor is stipulated according to technical conditions.

C) Measurement of DC resistance of stator winding in actual cold state: The deviation between the measured resistance of any phase and the average value of three phases should be no more than 3% of the average value of three phases, and the measured value should conform to HD.R-01-063.

D) Measurement of no-load current and loss: The deviation between the three-phase no-load current measured by motor and the average value of three-phase should be no more than 10% of the average value of phase, and the test value should conform to HD.R-01-063.


ZHEJIANG SHUDA MOTOR CO., LTD.

Address:Shan Louli Industrial Zone, Daxi Town, Wenling City, Zhejiang Province

Sales hotline:139 5864 3386

Service hotline:171 5667 1999

Fax:0576-86368833

Tel:0576-86382900

Website:anti-corruption.com.cn

Follow us

WeChat

Official website